Deutz generatorsstruktuur kenmerke:
1. V-tipe 8-silinder, 12-silinder en 16-silinder motore met gevorderde tegnologie
2. Enkel-silinder vier-klep-tegnologie
3. Die sentrale bedryfsbouglug word op die bouglugbasis geïnstalleer met verhoogte koeling
4. Elke brandstofpyn vir elke silinder
5. TEM elektroniese beheersisteem maak volledige outomatiese beheer en monitering van generatorbedryf moontlik
6.Verhoed lae uitstoot van skadelike stowwe deur die temperatuur van die verbrandingskamer te beheer
Genset Model | Wagstroom | PRIME POWER | Enjinmodel | Afmeting(MM) | Gewig (kg) |
Kva | Kva | ||||
KH-16GF | 22 | 20 | BFM3 G1 | 1580*800*1050 | 610 |
KH-24GF | 33 | 30 | BFM3 G2 | 1600*800*1050 | 630 |
KH-32GF | 44 | 40 | BFM3T | 1860*850*1050 | 750 |
KH-40GF | 55 | 50 | BFM3C | 1890*880*1100 | 800 |
KH-48GF | 66 | 60 | BF4M2012 | 2000*750*1300 | 1050 |
KH-60GF | 80 | 75 | BF4M2012C G1 | 2000*750*1300 | 1100 |
KH-72GF | 100 | 90 | BF4M2012C G2 | 2000*750*1300 | 1100 |
KH-80GF | 110 | 100 | BF4M1013EC G1 | 2150*750*1550 | 1200 |
KH-90GF | 125 | 112 | BF4M1013EC G2 | 2150*750*1550 | 1240 |
KH-104GF | 145 | 130 | BF4M1013FC | 2150*750*1550 | 1380 |
KH-128GF | 175 | 160 | BF6M1013EC G1 | 2600*1010*1700 | 1820 |
KH-144GF | 200 | 180 | BF6M1013EC G2 | 2600*1010*1700 | 1820 |
KH-150GF | 210 | 188 | BF6M1013FC G2 | 2600*1140*1800 | 1880 |
KH-160GF | 220 | 200 | BF6M1013FC G3 | 3060*1315*2035 | 2300 |
KH-200GF | 275 | 250 | TCD8.0 | 3060*1315*2035 | 2300 |
KH-240GF | 330 | 300 | TCD8.7 | 3060*1315*2035 | 2300 |
KH-260GF | 350 | 325 | TCD12.1G1 | 3060*1315*2035 | 2300 |
KH-300GF | 400 | 375 | TCD12.1G2 | 3060*1315*2035 | 2300 |
KH-360GF | 500 | 450 | TCD13.0G1 | 3208*1515*1975 | 2870 |
KH-400GF | 550 | 500 | TCD13.0G2 | 3208*1815*1978 | 3190 |
Genset Model | Standby krag KVA | PRIME POWER | Enjinmodel | Afmeting(MM) | Gewig (kg) |
Kva | Kva | ||||
KH-20GF | 28 | 25 | BFM3 G1 | 1580*800*1050 | 610 |
KH-28GF | 38 | 35 | BFM3 G2 | 1600*800*1050 | 630 |
KH-38GF | 53 | 47.5 | BFM3T | 1860*850*1050 | 750 |
KH-48GF | 65 | 60 | BFM3C | 1890*880*1100 | 800 |
KH-56GF | 75 | 70 | BF4M2012 | 2000*750*1300 | 1050 |
KH-65GF | 90 | 82 | BF4M2012C G1 | 2000*750*1300 | 1100 |
KH-80GF | 110 | 100 | BF4M2012C G2 | 2000*750*1300 | 1100 |
KH-90GF | 120 | 112 | BF4M1013EC G1 | 2150*750*1550 | 1200 |
KH-100GF | 140 | 125 | BF4M1013EC G2 | 2150*750*1550 | 1240 |
KH-110GF | 150 | 137.5 | BF4M1013FC | 2150*750*1550 | 1380 |
KH-134GF | 180 | 168 | BF6M1013EC G1 | 2600*1010*1700 | 1820 |
KH-160GF | 215 | 200 | BF6M1013EC G2 | 2600*1010*1700 | 1820 |
KH-168GF | 230 | 210 | BF6M1013FC G2 | 2600*1140*1800 | 1880 |
KH-176GF | 245 | 220 | BF6M1013FC G3 | 3060*1315*2035 | 2300 |
KH-212GF | 285 | 265 | TCD8.0 | 3060*1315*2035 | 2300 |
KH-256GF | 350 | 320 | TCD8.7 | 3060*1315*2035 | 2300 |
KH-300GF | 413 | 375 | TCD12.1G1 | 3060*1315*2035 | 2300 |
KH-320GF | 438 | 400 | TCD12.1G2 | 3060*1315*2035 | 2300 |
KH-375GF | 500 | 468 | TCD13.0G1 | 3208*1515*1975 | 2870 |
KH-400GF | 555 | 500 | TCD13.0G2 | 3208*1815*1978 | 3190 |