Caracteristicae structurales generatorum Deutz:
1. Motorum V-formis 8-cylindrorum, 12-cylindrorum et 16-cylindrorum cum technologia elaborata
2. Technologia unius cylindri cum quattuor valvis
3. Ignis centralis insertus in sedem fulguralem cum refrigeratione potentiata
4. Singulus coil ignis pro singulis cylindris
5. Systema electronicum TEM realizat operationem plene automaticam et monitorium functionis generatoris
6. Certamini ut parva emittantur quantitas materiae noxiae per combustionis camerae temperatura control.
Exemplum Genset | Standby Power | Potentia Prima | Engine Model | Dimensio (mm) | Pondus (KG) |
KVA | KVA | ||||
KH-16GF | 22 | 20 | BFM3 G1 | 1580*800*1050 | 610 |
KH-24GF | 33 | 30 | BFM3 G2 | 1600*800*1050 | 630 |
KH-32GF | 44 | 40 | BFM3T | 1860*850*1050 | 750 |
KH-40GF | 55 | 50 | BFM3C | 1890*880*1100 | 800 |
KH-48GF | 66 | 60 | BF4M2012 | 2000*750*1300 | 1050 |
KH-60GF | 80 | 75 | BF4M2012C G1 | 2000*750*1300 | 1100 |
KH-72GF | 100 | 90 | BF4M2012C G2 | 2000*750*1300 | 1100 |
KH-80GF | 110 | 100 | BF4M1013EC G1 | 2150*750*1550 | 1200 |
KH-90GF | 125 | 112 | BF4M1013EC G2 | 2150*750*1550 | 1240 |
KH-104GF | 145 | 130 | BF4M1013FC | 2150*750*1550 | 1380 |
KH-128GF | 175 | 160 | BF6M1013EC G1 | 2600*1010*1700 | 1820 |
KH-144GF | 200 | 180 | BF6M1013EC G2 | 2600*1010*1700 | 1820 |
KH-150GF | 210 | 188 | BF6M1013FC G2 | 2600*1140*1800 | 1880 |
KH-160GF | 220 | 200 | BF6M1013FC G3 | 3060*1315*2035 | 2300 |
KH-200GF | 275 | 250 | TCD8.0 | 3060*1315*2035 | 2300 |
KH-240GF | 330 | 300 | TCD8.7 | 3060*1315*2035 | 2300 |
KH-260GF | 350 | 325 | TCD12.1G1 | 3060*1315*2035 | 2300 |
KH-300GF | 400 | 375 | TCD12.1G2 | 3060*1315*2035 | 2300 |
KH-360GF | 500 | 450 | TCD13.0G1 | 3208*1515*1975 | 2870 |
KH-400GF | 550 | 500 | TCD13.0G2 | 3208*1815*1978 | 3190 |
Exemplum Genset | Praeparatio Potentia KVA | Potentia Prima | Engine Model | Dimensio (mm) | Pondus (KG) |
KVA | KVA | ||||
KH-20GF | 28 | 25 | BFM3 G1 | 1580*800*1050 | 610 |
KH-28GF | 38 | 35 | BFM3 G2 | 1600*800*1050 | 630 |
KH-38GF | 53 | 47.5 | BFM3T | 1860*850*1050 | 750 |
KH-48GF | 65 | 60 | BFM3C | 1890*880*1100 | 800 |
KH-56GF | 75 | 70 | BF4M2012 | 2000*750*1300 | 1050 |
KH-65GF | 90 | 82 | BF4M2012C G1 | 2000*750*1300 | 1100 |
KH-80GF | 110 | 100 | BF4M2012C G2 | 2000*750*1300 | 1100 |
KH-90GF | 120 | 112 | BF4M1013EC G1 | 2150*750*1550 | 1200 |
KH-100GF | 140 | 125 | BF4M1013EC G2 | 2150*750*1550 | 1240 |
KH-110GF | 150 | 137.5 | BF4M1013FC | 2150*750*1550 | 1380 |
KH-134GF | 180 | 168 | BF6M1013EC G1 | 2600*1010*1700 | 1820 |
KH-160GF | 215 | 200 | BF6M1013EC G2 | 2600*1010*1700 | 1820 |
KH-168GF | 230 | 210 | BF6M1013FC G2 | 2600*1140*1800 | 1880 |
KH-176GF | 245 | 220 | BF6M1013FC G3 | 3060*1315*2035 | 2300 |
KH-212GF | 285 | 265 | TCD8.0 | 3060*1315*2035 | 2300 |
KH-256GF | 350 | 320 | TCD8.7 | 3060*1315*2035 | 2300 |
KH-300GF | 413 | 375 | TCD12.1G1 | 3060*1315*2035 | 2300 |
KH-320GF | 438 | 400 | TCD12.1G2 | 3060*1315*2035 | 2300 |
KH-375GF | 500 | 468 | TCD13.0G1 | 3208*1515*1975 | 2870 |
KH-400GF | 555 | 500 | TCD13.0G2 | 3208*1815*1978 | 3190 |