Caracteristicae structurae generatorum Weichai:
1. Corpus ferraecum, structura reticularis, fortitudo magna et effectus refrigerationis excellens.
2. Praeditum oleo pompa manu pressa, filtro centrifugo olei per iter laterale et magno fluxu oleo pompa ad stabilitatem diesel motoris conservandam.
3. Pompa marina tota cuprea, urgentia connexionibus aquae frigidae et olei ad operationem fiduciam diesel motoris praestantem.
4. Filtro aeris novo designio, structura et firmitas optimata, altus efficax filtrationis, aër intromissus limpidior, structuram compactiorem et rationalem faciens.
5. Facilius ad elementum filtrum commutandum.
6. Nova structura olei panis est constructio motoris maritimi, quae augmentat aream dissipationis caloris olei et plene considerat eius proprietatem amortizandi ictum.
Exemplum Genset | Standby Potentia | Potentia Prima | Engine Model | Dimensio (mm) | Pondus(kg) |
KVA | KVA | ||||
KH-16GF | 22 | 20 | WP2.3D25E200 | 1680*800*1260 | 720 |
KH-24GF | 33 | 30 | WP2.3D33E200 | 1680*800*1260 | 740 |
KH-30GF | 42 | 38 | WP2.3D40E200 | 1760*650*1200 | 750 |
KH-36GF | 50 | 45 | WP2.3D48E200 | 2100*920*1500 | 980 |
KH-50GF | 69 | 63 | WP4.1D66E200 | 2350*730*1200 | 1100 |
KH-64GF | 88 | 80 | WP4.1D80E200 | 2350*730*1200 | 1150 |
KH-80GF | 110 | 100 | WP4.1D113E200 | 2350*730*1200 | 1200 |
KH-100GF | 138 | 125 | WP6D132E200 | 2410*930*1540 | 1260 |
KH-120GF | 165 | 150 | WP6D152E200 | 2410*930*1540 | 1280 |
KH-136GF | 187 | 170 | WP6D167E200 | 2410*930*1540 | 1300 |
KH-160GF | 220 | 200 | WP10D200E200 | 2860*1170*1800 | 1880 |
KH-184GF | 253 | 230 | WP10D238E200 | 2860*1170*1800 | 1900 |
KH-200GF | 275 | 250 | WP10D264E200 | 2860*1170*1800 | 1930 |
KH-250GF | 344 | 313 | WP10D320E200 | 2860*1170*1800 | 1950 |
KH-300GF | 413 | 375 | WP13D385E200 | 3200*950*1900 | 3230 |
KH-350GF | 482 | 438 | WP13D440E310 | 3200*950*1900 | 3300 |
KH-400GF | 550 | 500 | WP13D490E310 | 3200*950*1900 | 3340 |
KH-460GF | 633 | 575 | 6M33D572E200 | 3900*1500*2000 | 4500 |
KH-520GF | 715 | 650 | 6M33D633E200 | 3900*1500*2000 | 4580 |
KH-540GF | 743 | 675 | 6M33D670E200 | 3900*1500*2000 | 4660 |
KH-600GF | 825 | 750 | 6M33D725E310 | 3900*1500*2000 | 4760 |
KH-640GF | 880 | 800 | 8M33D800E200 | 4300*1800*2400 | 7100 |
KH-720GF | 990 | 900 | 8M33D890E200 | 4300*1800*2400 | 7180 |
KH-800GF | 1100 | 1000 | 8M33D975E310 | 4300*1800*2400 | 7300 |
KH-900GF | 1238 | 1125 | 12M33D1108E200 | 4300*1800*2130 | 7800 |
KH-1100GF | 1513 | 1375 | 12M33D1320E200 | 4300*1800*2130 | 7890 |
KH-1200GF | 1650 | 1500 | 12M33D1500E310 | 4300*1800*2130 | 7960 |
KH-1250GF | 1720 | 1563 | 16M33D1530E310 | 7210*2150*2340 | 13000 |
KH-1400GF | 1925 | 1750 | 16M33D1680E310 | 7210*2150*2340 | 13200 |
KH-1500GF | 2063 | 1875 | 16M33D1800E310 | 7210*2150*2340 | 13400 |
KH-1600GF | 2200 | 2000 | 16M33D1980E310 | 7210*2150*2340 | 13600 |
KH-1800GF | 2475 | 2250 | 12M55D2210E310 | 6620*2210*2500 | 14000 |
KH-2000GF | 2750 | 2500 | 12M55D2450E310 | 6620*2210*2500 | 14200 |
KH-2200GF | 3025 | 2750 | 12M55D2700E310 | 6620*2210*2500 | 14400 |
KH-2250GF | 3094 | 2813 | 16M55D2750E310 | 8230*2600*2700 | 22000 |
KH-2400GF | 3300 | 3000 | 16M55D2900E310 | 8230*2600*2700 | 22150 |
KH-2600GF | 3575 | 3250 | 16M55D3300E310 | 8230*2600*2700 | 22240 |
KH-3000GF | 4125 | 3750 | 16M55D3600E310 | 8230*2600*2700 | 22400 |
Exemplum Genset | Standby Potentia | Potentia Prima | Engine Model | Dimensio (mm) | Pondus(kg) |
KVA | KVA | ||||
KH-20GF | 28 | 25 | WP2.3D30E201 | 1680*800*1260 | 740 |
KH-30GF | 42 | 38 | WP2.3D41E201 | 1760*650*1200 | 750 |
KH-35GF | 48 | 44 | WP2.3D47E201 | 2100*920*1500 | 980 |
KH-40GF | 55 | 50 | WP2.3D58E201 | 2350*730*1200 | 1100 |
KH-60GF | 83 | 75 | WP4.1D80E201 | 2350*730*1200 | 1150 |
KH-75GF | 103 | 94 | WP4.1D95E201 | 2350*730*1200 | 1200 |
KH-90GF | 124 | 113 | WP4.1D120E201 | 2350*730*1200 | 1230 |
KH-100GF | 138 | 125 | WP6D132E201 | 2410*930*1540 | 1260 |
KH-120GF | 165 | 150 | WP6D158E201 | 2410*930*1540 | 1280 |
KH-145GF | 199 | 181 | WP6D180E201 | 2410*930*1540 | 1300 |
KH-150GF | 206 | 188 | WP10D200E201 | 2860*1170*1800 | 1880 |
KH-180GF | 248 | 225 | WP10D238E201 | 2860*1170*1800 | 1900 |
KH-200GF | 275 | 250 | WP10D264E201 | 2860*1170*1800 | 1930 |
KH-280GF | 385 | 350 | WP10D360E201 | 2860*1170*1800 | 1950 |
KH-300GF | 413 | 375 | WP13D385E201 | 3200*950*1900 | 3230 |
KH-400GF | 550 | 500 | WP13D510E311 | 3200*950*1900 | 3340 |
KH-450GF | 619 | 563 | 6M33D572E201 | 3900*1500*2000 | 4500 |
KH-520GF | 715 | 650 | 6M33D633E201 | 3900*1500*2000 | 4580 |
KH-550GF | 756 | 688 | 6M33D670E201 | 3900*1500*2000 | 4660 |
KH-600GF | 825 | 750 | 6M33D740E311 | 3900*1500*2000 | 4760 |
KH-640GF | 880 | 800 | 8M33D845E201 | 4300*1800*2400 | 7100 |
KH-720GF | 990 | 900 | 8M33D909E201 | 4300*1800*2400 | 7180 |
KH-800GF | 1100 | 1000 | 8M33D1012E311 | 4300*1800*2400 | 7300 |
KH-900GF | 1238 | 1125 | 12M33D1108E201 | 4300*1800*2130 | 7800 |
KH-1100GF | 1513 | 1375 | 12M33D1320E201 | 4300*1800*2130 | 7890 |
KH-1200GF | 1650 | 1500 | 12M33D1420E201 | 4300*1800*2130 | 7960 |
KH-1400GF | 1925 | 1750 | 16M33D1680E311 | 7210*2150*2340 | 13200 |
KH-1500GF | 2063 | 1875 | 16M33D1785E311 | 7210*2150*2340 | 13400 |
KH-1600GF | 2200 | 2000 | 16M33D1920E311 | 7210*2150*2340 | 13600 |
KH-2000GF | 2750 | 2500 | 12M55D2420E311 | 6620*2210*2500 | 14200 |
KH-2400GF | 3300 | 3000 | 16M55D2960E311 | 8230*2600*2700 | 22150 |
KH-2600GF | 3575 | 3250 | 16M55D3350E311 | 8230*2600*2700 | 22240 |
KH-3000GF | 4125 | 3750 | 16M55D3600E311 | 8230*2600*2700 | 22400 |
Turmae Servitii KAIHUA celeriter respondent ad omnia tua problemata. Distributores nostri per orbem terrarum amplam continuatam institutionem productorum KAIHUA accipiunt. Hoc efficit ut agens servitii et distributores nostros recte servitium peragant et cum norma Baifa, id garantat qualitatem et eventum servitii.
Servitium Prae-venditionis
-Servitium technicum praesale pro clientibus
-Auxilium in consilio conceptuali et selectione pro clientibus
-Auxilium in consilio et dispositione cubiculorum apparatum pro clientibus
-Accipere consultationem technicam clientium
Venditio servitii
Kaihua te praebebit schedula productionis, ut partus qualitas instrumenti conservet.
Sarcina
Kaihua genseta in casu ligni multiplexi ut norma cum exportando sarcinantur (nisi quae in FCL sunt)
Auxilium Technicum
Kaihua habet altam efficacem turmam praebentem altae qualitatis, universales comprehensivas professionales servitia.
Dum altam efficientiam et fiduciam servat ad laborandum 24/7 in situ.
Post Sales
-Apparatus institutio, debugging et operatio
-Inspectio ignis probatio
-Actio et sustentatio disciplina pro usoribus
-Remedium difficultatis et troubleshooting
-Partes OEM offerre
Servitium Securitatis
-Constituere usorum recordum post servitium et periodice examinare
-Organizare centralizatum disciplinam pro operatore usoris
-Nostri operarii secundum exigentiam emptoris in speciali condicione in officio esse possunt
Warrantia
Omnes usores Productorum Kaihua sine difficultate fruentur. Unumquodque nostrum productum saltem 1000 horas operationis/ 12 menses servitii warantiae tegitur.
Nostrum servitium department plenam responsabilitatem et celerem subsidium ad omnem quaestionem technicam praebebit, et solutionem ad normalem generatoris operationem resumendam praebebit. quaeso voca tuum distributorem localem vel contactum tuum venditionis procuratorem.
parce partes
Originalis fabricatoris partes sparsas servitium et mercator
Celer responsio in 24 horis globali consignment
Copyright © 2025 by Taizhou Kaihua Diesel Generator Sets Co., Ltd