Barcha kategoriyalar

Dizel generatorlar to'plami

Kategoriya: Generator to'plami (Dvigatel brendi), Cummins dunyodagi eng mashhur dvigatellaridan biri bo'lib, butun dunyoda keng qabul qilingan. Cummins Inc., global energiya yetakchisi, dvigatellar va ularga tegishli texnologiyalarni loyihalovchi, ishlab chiqaruvchi, tarqatuvchi va xizmat ko'rsatuvchi qo'shimcha biznes birliklaridan iborat korporatsiyadir.

Kirish

Dizel generator
Kategoriya: Generator to'plami (Dvigatel brendi), Cummins dunyodagi eng mashhur dvigatellaridan biri bo'lib, butun dunyoda keng qabul qilingan. Cummins Inc., global energiya yetakchisi, dvigatellar va ularga tegishli texnologiyalarni loyihalovchi, ishlab chiqaruvchi, tarqatuvchi va xizmat ko'rsatuvchi qo'shimcha biznes birliklaridan iborat korporatsiyadir.
1.JPG
Mahsulot tavsifi
Genset modeli Tayyor turish  Quvvat Bosh qudrat Motor modeli O'lchamlar (mm) Vazn(kg)
KVA KVA
KH-16GF 24 20 4B3.9-G11 1760*760*1380 700
KH-20GF 28 25 4B3.9-G1 1760*760*1380 730
KH- 22GF 30 27.5 4B3.9-G1 1760*760*1380 900
KH- 32GF 44 40 4BT3.9-G1 1760*760*1380 900
KH- 48GF 65 60 4BTA3.9-G2 1760*760*1380 980
KH- 50GF 70 62.5 QSB3.9-G2 1760*760*1380 1000
KH- 58GF 80 72.5 4BTA3.9-G11 1760*760*1380 1030
KH- 64GF 90 80 4BTA3.9-G11 1760*760*1380 1030
KH- 64GF 90 80 QSB3.9-G3 1760*760*1380 1230
KH- 75GF 103 94 6BT5.9-G1 2300*830*1700 1230
KH- 80GF 110 100 6BT5.9-G2 2300*830*1700 1310
KH- 80GF 110 100 QSB5.9-G2 2300*830*1700 1350
KH- 92GF 125 115 6BTA5.9-G2 2300*830*1700 1320
KH- 100GF 138 125 6BTAA5.9-G2 2350*830*1700 1360
KH- 100GF 140 125 QSB5.9-G3 2350*830*1700 1360
KH- 104GF 142 130 6BTAA5.9-G2 2350*830*1700 1360
KH- 125GF 170 156 6BTAA5.9-G12 2390*860*1850 1360
KH-128 GF 175 160 6C TA8.3-G1 2390*860*1850 1700
KH- 144GF 200 180 6C TA8.3-G2 2390*860*1850 1720
KH- 144GF 200 180 QSB6.7-G4 2500*960*1850 1800
KH- 160GF 220 200 6C TAA8.3-G2 2450*960*1850 1800
KH- 200GF 275 250 6LTAA8.9-G2 2500*960*1850 2060
KH- 200GF 275 250 QSL8.9-G4 2500*1200*1850 2100
KH- 240GF 330 300 6LTAA9.5-G1 2500*1160*1850 2200
KH- 360GF 500 450 QSZ13-G3 3400*1258*2050 3030
KH- 400GF 550 500 QSZ13-G10 3400*1258*2050 3130
KH-2 00GF 275 250 NT855-GA 3020*1100*1850 2350
KH- 240GF 330 300 QSM11-G2 2500*1160*1850 2420
KH- 248GF 340 310 MTAA11-G3 3020*1100*1850 2420
KH- 256GF 350 320 NTA855-G1B 3020*1100*1850 2870
KH- 275GF 375 344 NTA855-G2A 3020*1100*1850 2870
KH- 280GF 388 350 NTA855-G4 3020*1100*1850 2870
KH- 300GF 412 375 NTAA855-G7 3090*1100*1850 3100
KH- 320GF 438 400 QSNT-G3 3090*1300*1850 3200
KH- 320GF 450 NA NTAA855-G7A 3090*1100*1850 3100
KH- 360GF 500 450 QSNT-G4X 3090*1300*1850 3300
KH- 360GF 500 450 KTA19-G3 3400*1258*2050 4000
KH- 400GF 550 500 KTA19-G3A 3400*1258*2050 4040
KH- 400GF 550 500 KTA19-G4 3400*1258*2050 4200
KH- 460GF 650 NA KTA19-G8 3650*1500*2050 4500
KH- 460GF 650 575 KTAA19-G6 3650*1638*2050 4550
KH- 500GF 688 625 KTA19-G8A 3650*1638*2050 4550
KH- 500GF 688 NA KTAA19-G6A 3650*1638*2050 4550
KH- 508GF 700 635 QSK19-G4 3650*1638*2050 4890
KH- 520GF 715 650 Q5K19-G4 3650*1638*2050 4950
KH- 600GF 825 750 KTA38-G2 4550*2100*2320 6850
KH- 640GF 880 800 KTA38-G2B 4550*2100*2320 7000
KH- 728GF 1000 910 KTA38-G2A 4550*2100*2320 7150
KH- 800GF 1100 1000 KTA38-G5 4750*2100*2320 7430
KH- 900GF 1250 NA KTA38-G9 4750*2100*2320 7800
KH- 1000GF 1375 1250 QSK38-G5 5000*2200*2500 7900
KH- 1000GF 1375 1250 KTA50-G3 5000*2200*2500 9600
KH- 1120GF 1540 1400 KTA50-G8 5820*2200*2800 11000
KH- 1200GF 1650 1500 KTA50-GS8 5820*2200*2800 11000
KH- 1340GF 1875 1675 KTA50-G15A 5820*2200*2800 11300
KH- 1500GF 2000 1875 KTA50-G16A 5820*2200*2800 11400
KH- 1640GF 2250 2050 QSK60-G4 5820*2200*2800 15500
KH- 1800GF 2500 2250 QSK60-G8 5820*2200*2800 16000
KH- 2000GF 2750 2500 QSK60-G23 5820*2200*2800 16500

                                                  

2.jpg

Ko'proq mahsulotlar

  • MTU dizel generator

    MTU dizel generator

  • Mobil generator kompluati

    Mobil generator kompluati

  • Deutz Дизель Генератори

    Deutz Дизель Генератори

  • Shangchai(SDEC) Дизель Генератори

    Shangchai(SDEC) Дизель Генератори

Bezbosh xabar yuboring

Bizning ifodachisi tez orada siz bilan bog'lanadi.
Email
Mobil
WhatsApp
Ism
Kompaniya nomi
Xabar
0/1000