All Categories

Marine Diesel Generator

Category: Generator Set(Fuel). Kaihua diesel generator design is new and reasonable structure. Open-frame diesel generator with steel bending beam welded into the frame structure, high strength and rigidity; diesel generators can be equipped with the base fuel tank, meet eight hours operation.

Introduction

Marine Geneartor
Category: Generator Set(Fuel). Kaihua diesel generator design is new and reasonable structure. Open-frame diesel generator with steel bending beam welded into the frame structure, high strength and rigidity; diesel generators can be equipped with the base fuel tank, meet eight hours operation.
1.jpg2.JPG
Product Description
● CCS,BV,ABS,RINA,KR CERTIFICATE
● IMO EMISSION CERTIFICATE
● STAMFORD,LEROY-SOMER,MARATHON MARINE ALTERNATOR AS OPTIONAL
● HEAT EXCHANGER COOLED AND KEEL COOLEDAS OPTIONAL
4.JPG3.JPG
             
Generator spec. Engine Spec. Dimensions Weight
Model Rated power Frenquency/voltage Engine model Power/Speed
kW kVA Hz/ V kW/RPM L×W×H(mm) (kg)
CCFJ40J 40 50 50/400 4BTA3.9-GM47 47/1500 1670*850*1270 800
CCFJ50J 50 62.5 50/400 6BT5.9-GM83 83/1500 1900*900*1300 1000
CCFJ64J 64 80 50/400 6BT5.9-GM83 83/1500 1900*900*1300 1100
CCFJ75J 75 93.8 50/400 6BTA5.9-GM100 100/1500 1900*900*1300 1250
CCFJ90J 90 112.5 50/400 6BTA5.9-GM100 100/1500 2020*900*1300 1300
CCFJ100J 100 125 50/400 6CT8.3-GM115 115/1500 2080*900*1360 1650
CCFJ120J 120 150 50/400 6CT8.3-GM115 115/1500 2120*900*1360 1700
CCFJ150J 150 187.5 50/400 6CTA8.3-GM155 155/1500 2220*1000*1790 1720
CCFJ160J 160 200 50/400 6LTAA8.9-GM200 200/1500 2250*1000*1790 1750
CCFJ200J 200 250 50/400 N855-DM 240/1500 2760*1000*1790 2700
CCFJ250J 250 312.5 50/400 N855-DM 284/1500 2760*1000*1790 2800
CCFJ280J 280 350 50/400 N855-DM 317/1500 2998*1000*1790 2950
CCFJ300J 300 375 50/400 K19-DM 358/1500 2998*1000*1790 3360
CCFJ350J 350 437.5 50/400 K19-DM 410/1500 3170*1000*1920 3480
CCFJ400J 400 500 50/400 K19-DM 448/1500 3170*1000*1920 3650
CCFJ680J 680 850 50/400 K38-DM 746/1500 4050*1500*2480 7200
CCFJ800J 800 1000 50/400 K38-DM 880/1500 4100*1500*2480 7350
CCFJ1000J 1000 1250 50/400 K50-DM 1097/1500 4500*1500*2480 9500

More Products

  • MTU Diesel Generator

    MTU Diesel Generator

  • Deutz Diesel Generator

    Deutz Diesel Generator

  • Shangchai(SDEC) Diesel Generator

    Shangchai(SDEC) Diesel Generator

  • Mobile Generator Set

    Mobile Generator Set

Get a Free Quote

Our representative will contact you soon.
Email
Mobile
WhatsApp
Name
Company Name
Message
0/1000