Shangchai(SDEC) Diesel Generator

Shangchai generators structural features:
1. Integral crankshaft, gantry body, flat-cut connecting rod, short piston, compact and reasonable appearance, strong matching adaptability, can be interchanged with the old 135 diesel engine;
2. Adopt a new type of necked combustion chamber to increase the fuel injection pressure, improve the combustion process, and meet the environmental protection indicators: the exhaust pollutant emission value meets the requirements of JB8891-1999, and the noise meets the requirements of GB14097-1999 with a margin;
3. Optimized design of lubrication and cooling system, reduce the number of external pipelines and parts, and use the integral brushless alternator to greatly improve the three leakage and greatly enhance the reliability.
4. It is matched with J98 and J114b exhaust gas turbochargers, which has strong plateau working ability. When used in plateau areas with an altitude of 5000m, the power drop is less than 3%;

50HZ

Genset Model Standby Power Prime Power Engine Model Dimension(mm) Weight(kg)
KVA KVA
KH-8GF 11 10 3Z1.1-G42 1350*600*1100 550
KH-10GF 14 13 3ZT1.1-G42 1350*600*1100 600
KH-12GF 17 15 4Z2.3-G21 1350*600*1100 610
KH-16GF 22 20 4Z2.7-G21 1450*600*1100 630
KH-25GF 34 31 4Z3.2-G21 1500*600*1100 700
KH-32GF 44 40 4ZT3.2-G21 1500*600*1100 750
KH-40GF 55 50 4ZT3.5-G21 1600*600*1100 760
KH-50GF 69 63 SC4H95D2 1910*900*1170 940
KH-64GF 88 80 SC4H115D2 1910*900*1170 970
KH-80GF 110 100 SC4H140D2 2100*890*1260 1040
KH-90GF 124 113 SC4H160D2 2100*890*1260 1060
KH-100GF 138 125 SC4H180D2 2100*890*1260 1080
KH-120GF 165 150 SC7H205D2 2500*890*1400 1500
KH-150GF 207 188 SC7H250D2 2500*950*1440 1540
KH-160GF 220 200 SC8D280D2 2520*980*1500 1560
KH-180GF 247 225 SC9D310D2 2600*1050*1550 1800
KH-200GF 275 250 SC9D340D2 2750*1060*1500 2650
KH-250GF 344 313 SC13G420D2 3110*1280*1750 2870
KH-280GF 385 350 SC12E460D2 3180*1100*1600 2900
KH-300GF 413 375 SC15G500D2 3150*1280*1750 2930
KH-320GF 440 400 SC13E550D2 3250*1400*1750 2980
KH-400GF 550 500 6ETAA12.8-G310 3250*1280*1750 3000
KH-450GF 619 563 SC27G755D2 3550*1400*2000 4450
KH-500GF 688 625 SC27G830D2 3550*1520*1970 4500
KH-550GF 757 688 SC27G900D2 3610*1520*2060 4600
KH-600GF 825 750 6KTAA25-G32 3800*1600*2150 4700
KH-660GF 908 825 6KTAA25-G31 3800*1600*2150 4800
KH-720GF 990 900 6KTAA25-G320 4390*1600*2100 5800
KH-800GF 1100 1000 6KTAA25-G321 4390*1600*2100 5860
KH-900GF 1238 1125 6WTAA35-G310 4600*1800*2400 7200
KH-1000GF 1375 1250 6WTAA35-G311 4600*1800*2400 7300
KH-1100GF 1513 1375 12KTA58-G36 4400*2200*2510 7340
KH-1250GF 1719 1563 12KTA58-G35 4550*2200*2510 7360
KH-1350GF 1857 1688 12KTA58-G34 4550*2200*2510 7380
KH-1500GF 2063 1875 12KTA58-G33 4550*2200*2510 7400
KH-1600GF 2200 2000 12KTA58-G32 4650*2200*2510 7420
KH-1800GF 2475 2250 12KTA58-G31 4650*2450*2510 7440

60HZ

Genset Model Standby Power Prime Power Engine Model Dimension(mm) Weight(kg)
KVA KVA
KH-8GF 11 10 3Z1.1-G42 1350*600*1100 550
KH-10GF 14 13 3ZT1.1-G42 1350*600*1100 600
KH-12GF 17 15 4Z2.3-G21 1350*600*1100 610
KH-16GF 22 20 4Z2.7-G21 1450*600*1100 630
KH-25GF 34 31 4Z3.2-G21 1500*600*1100 700
KH-32GF 44 40 4ZT3.2-G21 1500*600*1100 750
KH-40GF 55 50 4ZT3.5-G21 1600*600*1100 760
KH-50GF 69 63 4HT4.3-G22 1910*900*1170 940
KH-64GF 88 80 4HT4.3-G23 1910*900*1170 970
KH-80GF 110 100 4HTAA4.3-G21 2100*890*1260 1040
KH-90GF 124 113 4HTAA4.3-G23 2100*890*1260 1060
KH-100GF 138 125 4HTAA4.3-G22 2100*890*1260 1080
KH-120GF 165 150 6HTAA6.5-G22 2500*890*1400 1500
KH-150GF 207 188 6HTAA6.5-G23 2500*950*1440 1540
KH-160GF 220 200 6DTAA8.9-G21 2520*980*1500 1560
KH-180GF 247 225 6DTAA8.9-G24 2600*1050*1550 1800
KH-200GF 275 250 6DTAA8.9-G23 2750*1060*1500 2650
KH-250GF 344 313 6ETAA11.8-G22 3110*1280*1750 2870
KH-280GF 385 350 6ETAA11.8-G21 3180*1100*1600 2900
KH-300GF 413 375 6ETAA12.8-G22 3150*1280*1750 2930
KH-320GF 440 400 6ETAA12.8-G32 3250*1400*1750 2980
KH-400GF 550 500 6ETAA12.8-G310 3250*1280*1750 3000
KH-450GF 619 563 6KTAA25-G310 3550*1400*2000 4450
KH-500GF 688 625 6KTAA25-G39 3550*1520*1970 4500
KH-550GF 757 688 6KTAA25-G38 3610*1520*2060 4600
KH-600GF 825 750 6KTAA25-G32 3800*1600*2150 4700
KH-660GF 908 825 6KTAA25-G31 3800*1600*2150 4800
KH-720GF 990 900 6KTAA25-G320 4390*1600*2100 5800
KH-800GF 1100 1000 6KTAA25-G321 4390*1600*2100 5860

Service

KAIHUA Service Teams are fast responsive to all you problem. Our distributor around the world receives extensive ongoing KAIHUA product training. This ensures that our service agent and distributor will correctly carry out service and with Baifa standard, it guarantees the service quality and outcome.
Pre-Sale Service

fb38060c-c2b8-4edd-8105-f9ba2a8f13c9.jpg
-The presale technical service for the customers
-Assist the conceptual design and selecting for the customers
-Assist the equipment room design and arrangement for the customers
-Accept the technical consultation of the customers
Sale of service

1704444712983147.jpg
Kaihua will provide you with the production schedule to ensure the delivery quality of equipment.
Packing

DSC00519.JPG
Kaihua gensets are packed in plywood case as standard when exporting (except for those are in FCL)
Technical Support

1704444876659720.jpg
Kaihua has a high effective team providing high-quality, all-round comprehensive professional services.
While maintain highly efficient and reliable to work 24/7 at site.
After Sales

1704444994960856.jpg
-Equipment installation, debugging and operation
-The fire-fighting inspection testing
-The action and maintenance training for the users
-Remedy of the trouble and troubleshooting
-Offer OEM parts
Service Guarantee

1704445039377431.jpg
-Set up users’ record trail after service and termly check
-Organize centralized training for the operator of user
-Our staff can be on duty according to customer’s -requirement in special condition
Warranty
All Kaihua Product users will enjoy the hassle free. Every of our product is covered at least 1000 hours operation hours/ 12 month of warranty service.
Our service department will be full-responsibly and fast support to every technical issue, and provide solution to resume normal generator running. please call your local distributor or contact your sales manager.
Spare Parts
Original manufacturer authorized spare parts service and dealer
Rapid response in 24 hours global consignment

Recommended Products

Get a Free Quote

Our representative will contact you soon.
Email
0/100
Mobile
0/16
WhatsApp
Name
0/100
Company Name
0/200
Message
0/1000
Facebook Facebook YouTube YouTube Linkedin Linkedin WhatsApp WhatsApp TopTop